Specifications
Counter Electrode |
Voltage Output |
± 12V max |
Current Output |
± 12mA max |
Slew Rate |
1mV/s to 10V/s |
Protection |
Thermal, overload and short-circuit |
Working Electrode |
Current Measure |
From 1nA to 10mA Full Scale in 8 ranges |
Current Resolution |
From 1pA at 1nA Full Scale to 1μA at 10mA Full Scale |
Measuring Accuracy |
± 0,2% & 0,1% (conversion at Full Scale) |
Reference Electrodes |
Input Impedance |
> 1TΩ |
Input Capacitance |
< 20pF (1m cable) |
Biasing Current |
< 2pA at 25°C |
Common Mode Rejection |
> 50dB full frequency response |
Voltage Range |
± 10V max |
Polarization Capability |
Voltage |
± 4V max |
Current |
± 10mA max |
Voltage Resolution |
1mV |
Current Resolution |
1pA |
Accuracy |
± 0,2% & 0,1% (conversion at Full Scale) |
Response Time |
Potensiostatic Rise Time |
10μs resistive load (1000Ω) |
Galvanostatic Rise Time |
25μs resistive load (1000Ω) |
Meters and Interface |
A/D Converter |
16 BIT |
D/A Converter |
16 BIT |
Temperature Meter |
0 to +100°C with PT1000 probe (0,1°C resolution and ± 0,2°C accuracy) |
pH Meter |
-2,000 to +16,000pH (0,001pH resolution and ± 0,005pH accuracy) |
Sampling Interval |
200μs |
Digital Interface |
Connection |
USB with full instrument control (baud rate 57600 – N – 8 – 1) |
Memory |
EEPROM 64kB – SRAM 32kB |
Digital Burette |
Model 235 with 1000μL calibrated syringe (optional) |
Peristaltic Pump Control |
Start/stop and direct/reverse flow |
Cell Connections |
Working Electrode |
Hanging Drop Mercury Electrode (110 x Ø6mm capillary – Ø0,1mm)
Rotating Disk Electrode (100 to 5000rpm)
Solid Electrode Tips |
Counter Electrode |
Platinum wire (Ø0,8 x 5mm) with 2mm ball ending |
Reference Electrode |
Ag/AgCl (3M KCl electrolyte)
Calomel (Sat. KCl electrolyte) |
Stirrer |
Magnetic or overhead propeller (computer controlled) |
Power Supply and Dimensions |
Voltage Mains |
115 or 230V AC ±10% 50/60Hz |
Power Consumption |
40VA max |
Dimensions (L x W x H) |
270 x 320 x 350mm |
Weight |
8kg |
Specifications are subject to change without previous notice
Techniques
Detection |
AD |
Amperometric Detection |
PD |
Potentiometric Detection |
DSA |
Double Step Amperometry |
DSV |
Double Step Potentiometry |
PAD |
Pulsed Amperometric Detection |
Voltammetric |
LSV |
Linear Scan Voltammetry |
CYV |
Cyclic Voltammetry |
GLV |
Galvanostatic Linear Voltammetry |
GCV |
Galvanostatic Cyclic Voltammetry |
SWV |
Square Wave Voltammetry |
NPV |
Normal Pulse Voltammetry |
ACV |
Alternating Current Voltammetry |
DPV |
Differential Pulse Voltammetry |
DNV |
Differential Normal Pulse Voltammetry |
DAV |
Differential Alternate Pulse Voltammetry |
Stripping |
LSS |
Linear Scan Stripping |
ACS |
Alternate Current Stripping |
SWS |
Square Wave Stripping |
DAS |
Differential Stripping |
DPS |
Differential Pulse Stripping |
DNS |
Differential Normal Pulse Stripping |
PSA |
Potentiometric Stripping Analysis |
CCSA |
Constant Current Stripping Analysis |
Specifications are subject to change without previous notice
Accessories
4330/MV |
Hanging Drop Mercury Electrode |
RDEO |
Rotating Disk Electrode system |
RDE/GC/3 |
3mm Glassy Carbon tip for Rotating Disk Electrode |
RDE/AU/3 |
3mm Gold tip for Rotating Disk Electrode |
435/LF |
Propeller stirrer |
435/LFP |
Paddle for Propeller stirrer |
4330/PX |
30mL PMMA cell for Screen Printed Electrodes |
493/6JZ |
Support for 492/X tips |
492/X |
Generic tip for 493/6JZ support |
DPR/C110 |
Screen Printed Electrodes 25pz |
191/CP |
Screen Printed Electrodes cables |
303/SCG/6JZ |
Calomel reference electrode |
373/SSG/6JZ |
Silver chloride reference electrode |
805/SPG/6JZ |
Platinum counter electrode |
805/SPG/6JZ-C |
Platinum counter electrode with jacket |
411/CPG/6JZ |
Combined pH electrode |
430/GC |
30mL Pyrex cell |
430/QZ |
30mL Quartz cell |
430/LC |
30mL Pyrex cell with Luggin capillary |
430/TE |
30mL PTFE cell |
430/TJ |
30mL Pyrex cell with thermostatic jacket |
430/MC |
1-5mL Pyrex microcell with embedded Platinum electrode |
430/SB |
Magnetic stirrer bar |
430/LU |
Luggin capillary for 430/LC cell |
430/MHS |
PTFE cap for NS6 conical tapered fitting |
430/PV |
Manual vacuum pump for Hanging Drop Mercury Electrode |
430/GT |
Mercury trap for 430/PV manual vacuum pump |
430/C |
Capillary for Models 430, 433, 4330 and 4330/P |
430/OC-2025 |
Capillary side sealing gasket |
430/OB-3193 |
Cell sealing gasket |
430/SI |
Capillary silicone sealing gasket |
430/TR-2007 |
Capillary PTFE sealing gasket |
191/5BN2 |
Set of 5 WE, RE and CE cables for 4330 & 4330/P |
191/USB |
USB cable A – B |
191/GPC |
Grid power cable |
9811 |
Saturated KCl solution |
In addition to these specific accessories, a complete rage of standard and selective electrodes is available from Amel.