Large currents and reliability, all you need for batteries and more..

Model 2550 is the big-brother of Model 2551 with increased maximum current capability on a single channel.

It is very popular for material science and batteries characterization, thanks to its stability and accuracy. New features make it much more attractive, among them positive feedback control, IR compensation and manual or automatic current ranging.


Counter Electrode
Voltage Output ± 16V max
Current Output ± 5,5A max
Slew Rate 0,01mV/s to 10V/s
Protection Thermal, overload and short-circuit
Working Electrode
Current Measure From 100nA to 10A Full Scale in 9 ranges
Current Resolution From 100pA at 100nA Full Scale to 1mA at 10A Full Scale
Measuring Accuracy < 1% of Full Scale in 100nA to 1μA ranges
< 0,25% of Full Scale in 10μA to 1A ranges
< 5% of Full Scale in 10A range
Reference Electrode
Input Impedance > 1TΩ
Input Capacitance < 20pF (1m cable)
Biasing Current < 10pA at 25°C
Common Mode Rejection > 60dB full frequency response
Voltage Range ± 10V max or ± 50V max
Input BNC Grounded outer contact
Polarization Capability
Voltage ± 10V max
Current ± 5A max
Voltage Resolution 0,1mV
Current Resolution 100pA
Accuracy ± 0,2% & 0,1% (conversion at Full Scale)
IR Compensation
Positive Feedback Range 2Ω to 100MΩ (depending on current range)
Response Time
Potentiostatic Rise time < 1μs resistive load (1000Ω)
Galvanostatic Rise time < 17μs resistive load (1000Ω)
Meters and Interfaces
A/D Converter 16 BIT
D/A Converter 16 BIT
Temperature Meter 0 to +100°C with PT1000 probe (0,1°C resolution and ± 0,2°C accuracy)
Sampling Interval 200 µs
Digital Interface
Connection USB with full instrument control (baud rate 57600 – N – 8 – 1)
Memory EEPROM 64kB – SRAM 32kB
Port Output 8 external accessories
I/O Port 8 optional
Cell Connections
Cables 2, 3, 4 cables. BNC connector for Reference (Hi & Low) and PL258 for Working and Counter electrodes to 4mm banana connectors
Power Supply and Dimensions
Voltage Mains 115 or 230V AC ±10% 50/60Hz
Power Consumption 120VA max
Dimensions (L x W x H) 400 x 440 x 145mm
Weight 15kg

Specifications are subject to change without previous notice

Detection
AD Amperometric Detection
PD Potentiometric Detection
DSA Double Step Amperometry
DSV Double Step Potentiometry
PAD Pulsed Amperometric Detection
Voltammetric
LSV Linear Scan Voltammetry
CYV Cyclic Voltammetry
GLV Galvanostatic Linear Voltammetry
GCV Galvanostatic Cyclic Voltammetry
SWV Square Wave Voltammetry
NPV Normal Pulse Voltammetry
ACV Alternating Current Voltammetry
DPV Differential Pulse Voltammetry
DNV Differential Normal Pulse Voltammetry
DAV Differential Alternate Pulse Voltammetry
Stripping
LSS Linear Scan Stripping
ACS Alternate Current Stripping
SWS Square Wave Stripping
DAS Differential Stripping
DPS Differential Pulse Stripping
DNS Differential Normal Pulse Stripping
PSA Potentiometric Stripping Analysis
CCSA Constant Current Stripping Analysis

Specifications are subject to change without previous notice