The Polarographic Analyzer Model 4330/P combines two instruments for electrochemical trace analysis of heavy metals in organic compounds. Thank to the electronic evolution AMEL have combines both voltammetric and polarographic techniques with Potentiometric ones (PSA Potentiometric stripping analysis). In this way it is now possoible to select the most appropriate technique to carry out the analysis. With Model 4330/P you may perform analysis of heavy metals in organic compounds at μg/l. level. The instrument is supplied with Windows software.
Model 4330/P is the historical polarograph by AMEL, developed to be used with the built-in mercury valve that can be operated both as Hanging Drop Mercury Electrode or Dropping Mercury Electrode. Thanks to the constantly updated circuitry, detection limits can be pushed below the ppb level.
Detection | |
AD | Amperometric Detection |
PD | Potentiometric Detection |
DSA | Double Step Amperometry |
DSV | Double Step Potentiometry |
PAD | Pulsed Amperometric Detection |
Voltammetric | |
LSV | Linear Scan Voltammetry |
CYV | Cyclic Voltammetry |
GLV | Galvanostatic Linear Voltammetry |
GCV | Galvanostatic Cyclic Voltammetry |
SWV | Square Wave Voltammetry |
NPV | Normal Pulse Voltammetry |
ACV | Alternating Current Voltammetry |
DPV | Differential Pulse Voltammetry |
DNV | Differential Normal Pulse Voltammetry |
DAV | Differential Alternate Pulse Voltammetry |
Stripping | |
LSS | Linear Scan Stripping |
ACS | Alternate Current Stripping |
SWS | Square Wave Stripping |
DAS | Differential Stripping |
DPS | Differential Pulse Stripping |
DNS | Differential Normal Pulse Stripping |
PSA | Potentiometric Stripping Analysis |
CCSA | Constant Current Stripping Analysis |
Specifications are subject to change without previous notice
Counter Electrode | |
Voltage Output | ± 12V max |
Current Output | ± 12,5mA max |
Slew Rate | 1mV/s to 10V/s |
Protection | Thermal, overload and short-circuit |
Working Electrode | |
Current Measure | From 1nA to 10mA Full Scale in 8 ranges |
Current Resolution | From 1pA at 1nA Full Scale to 1μA at 10mA Full Scale |
Measuring Accuracy | ± 0,2% & 0,1% (conversion at Full Scale) |
Reference Electrodes | |
Input Impedance | > 1TΩ |
Input Capacitance | < 20pF (1m cable) |
Biasing Current | < 2pA at 25°C |
Common Mode Rejection | > 50dB full frequency response |
Voltage Range | ± 10V max |
Polarization Capability | |
Voltage | ± 4V max |
Current | ± 10mA max |
Voltage Resolution | 1mV |
Current Resolution | 1pA |
Accuracy | ± 0,2% & 0,1% (conversion at Full Scale) |
Response Time | |
Potentiostatic Rise Time | 10μs resistive load (1000Ω) |
Galvanostatic Rise Time | 25μs resistive load (1000Ω) |
Meters and Interface | |
A/D Converter | 16 BIT |
D/A Converter | 16 BIT |
Sampling Interval | 200μs |
Digital Interface | |
Connection | USB with full instrument control (baud rate 57600 – N – 8 – 1) |
Memory | EEPROM 64kB – SRAM 32kB |
Cell Connection electrodes | |
Working Electrode | Dropping Mercury Electrode (110 x Ø6mm capillary - Ø0,1mm) Hanging Drop Mercury Electrode (110 x Ø6mm capillary - Ø0,1mm) |
Counter Electrode | Platinum wire Ø1x5mm |
Reference Electrode | Ag/AgCl (saturated KCl electrolyte) |
Stirrer | Magnetic (computer controlled) |
Power Supply and Dimensions | |
Voltage Mains | 115 or 230V AC ±10% 50/60Hz |
Power Consumption | 40VA max |
Dimensions (L x W x H) | 250 x 270 x 350mm |
Weight | 12kg |
Specifications are subject to change without previous notice
For more information visit: https://www.amelchem.com/4330-p/