The Polarographic Analyzer Model 4330/P combines two instruments for electrochemical trace analysis of heavy metals in organic compounds. Thank to the electronic evolution AMEL have combines both voltammetric and polarographic techniques with Potentiometric ones (PSA Potentiometric stripping analysis). In this way it is now possoible to select the most appropriate technique to carry out the analysis. With Model 4330/P you may perform analysis of heavy metals in organic compounds at μg/l. level. The instrument is supplied with Windows software.


Model 4330/P is the historical polarograph by AMEL, developed to be used with the built-in mercury valve that can be operated both as Hanging Drop Mercury Electrode or Dropping Mercury Electrode. Thanks to the constantly updated circuitry, detection limits can be pushed below the ppb level.
Detection
ADAmperometric Detection
PDPotentiometric Detection
DSADouble Step Amperometry
DSVDouble Step Potentiometry
PADPulsed Amperometric Detection
Voltammetric
LSVLinear Scan Voltammetry
CYVCyclic Voltammetry
GLVGalvanostatic Linear Voltammetry
GCVGalvanostatic Cyclic Voltammetry
SWVSquare Wave Voltammetry
NPVNormal Pulse Voltammetry
ACVAlternating Current Voltammetry
DPVDifferential Pulse Voltammetry
DNVDifferential Normal Pulse Voltammetry
DAVDifferential Alternate Pulse Voltammetry
Stripping
LSSLinear Scan Stripping
ACSAlternate Current Stripping
SWSSquare Wave Stripping
DASDifferential Stripping
DPSDifferential Pulse Stripping
DNSDifferential Normal Pulse Stripping
PSAPotentiometric Stripping Analysis
CCSAConstant Current Stripping Analysis

Specifications are subject to change without previous notice

Counter Electrode
Voltage Output± 12V max
Current Output± 12,5mA max
Slew Rate1mV/s to 10V/s
ProtectionThermal, overload and short-circuit
Working Electrode
Current MeasureFrom 1nA to 10mA Full Scale in 8 ranges
Current ResolutionFrom 1pA at 1nA Full Scale to 1μA at 10mA Full Scale
Measuring Accuracy± 0,2% & 0,1% (conversion at Full Scale)
Reference Electrodes
Input Impedance> 1TΩ
Input Capacitance< 20pF (1m cable)
Biasing Current< 2pA at 25°C
Common Mode Rejection> 50dB full frequency response
Voltage Range± 10V max
Polarization Capability
Voltage± 4V max
Current± 10mA max
Voltage Resolution1mV
Current Resolution1pA
Accuracy± 0,2% & 0,1% (conversion at Full Scale)
Response Time
Potentiostatic Rise Time10μs resistive load (1000Ω)
Galvanostatic Rise Time25μs resistive load (1000Ω)
Meters and Interface
A/D Converter16 BIT
D/A Converter16 BIT
Sampling Interval200μs
Digital Interface
ConnectionUSB with full instrument control (baud rate 57600 – N – 8 – 1)
MemoryEEPROM 64kB – SRAM 32kB
Cell Connection electrodes
Working ElectrodeDropping Mercury Electrode (110 x Ø6mm capillary - Ø0,1mm)
Hanging Drop Mercury Electrode (110 x Ø6mm capillary - Ø0,1mm)
Counter ElectrodePlatinum wire Ø1x5mm
Reference ElectrodeAg/AgCl (saturated KCl electrolyte)
StirrerMagnetic (computer controlled)
Power Supply and Dimensions
Voltage Mains115 or 230V AC ±10% 50/60Hz
Power Consumption40VA max
Dimensions (L x W x H)250 x 270 x 350mm
Weight12kg

Specifications are subject to change without previous notice

 