+91 86553 48837

sales@phadkeinstruments.com

Squidstat Solo ±100 mA Potentiostat Galvanostat

A cost-effective, single-channel potentiostat designed for everyday electrochemical measurements.

Ideal for education, method development, and general research applications where simplicity, reliability, and flexibility are essential.

Description

  • Single-channel potentiostat/galvanostat

  • Current range: ±100 mA max

  • Voltage scan range: ±10 V

  • Compatible with Windows, MacOS, and Ubuntu via the Squidstat User Interface software and Application Programming Interface

  • Onboard memory (16 GB) automatically backs up all channel data for future recovery

  • Multiple units can run simultaneously with other Squidstat models

  • Made in USA

General Specifications
Values
Channels Per Unit
1
Operating Modes
Pot / Gal / ZRA
Cell Connections
5 electrode
ADC/DAC Resolution
16-bit resolution
Slew Rate (1 kΩ load)
5 kV/s (-1 V to +1V)
Shortest DC data recording interval
200 µs
Shortest DC data hardware sampling interval
7.5 µs
Floating/Ground Mode
Both (Switchable)
Input Impedance
10 Tera-Ω (typical)
Input Bias Current
10 pA (typical)
Data Backup Memory
16 GB onboard
Dimension and Weight
24 L x 17 W x 6 H cm, 1 kg
Channel Cable Length
1 m
Computer Interface
1 USB per unit
Temperature Operating Range
0 to 40 ℃
Min/Max Scan Rate
300 µV/s minimum, 25 V/s maximum with 10 mV sampling
Smallest Pulse Width
375 µs
Smallest Potential Step for Sweep Voltammetry
0.003% (30.52 ppm) of range, 300 μV min
Square Wave Voltammetry Max Frequency
1 kHz (-1 V to +1V)
Power Supply Requirements
100 – 240 VAC, 50 – 60 Hz

 

Potentiostatic Mode

Potentiostatic Input/Output
Values
Compliance Voltage
±12 V
Voltage Scan Range
±10 V
Number of Voltage Ranges
1 range, [±10 V]
Applied Voltage Accuracy
0.1% of setpoint, 1 mV min
Applied Voltage Resolution
0.003% (30.52 ppm) of range, 300 μV min
Measured Voltage Accuracy
0.1% of measured, 1 mV min
Measured Voltage Resolution
0.003% (30.52 ppm) of range, 300 μV min
Time Resolution
10 ns
iR Compensation Limits
1.82 V max

 

Galvanostatic Mode

Galvanostatic Input/Output
Values
Current Range
±100 mA
Number of Current Ranges
8 ranges, [10 nA to 100 mA]
Applied Current Accuracy
0.1% of range, 1 nA min
Applied Current Resolution
0.003% (30.52 ppm) of range, 300 fA min
Measured Current Accuracy
0.1% of range, 1 nA min
Measured Current Resolution
0.003% (30.52 ppm) of range, 300 fA min

 

Experiments

  • Battery Capacity
  • Charge / Discharge (Constant C / Constant V)
  • Charge / Discharge (Constant R / Constant P)
  • Chronoamperometry
  • Chronopotentiometry
  • Constant Power
  • Constant Resistance
  • Cyclic Voltammetry (CV)
  • Differential Pulse Voltammetry (DPV)​​
  • Galvanostatic Intermittent Titration Technique (GITT)
  • Potentiostatic Intermittent Titration Technique (PITT)
  • Linear Sweep Amperometry
  • Linear Sweep Voltammetry (LSV)
  • Normal Pulse Voltammetry
  • Open Circuit Potential Monitoring
  • Rotating Ring Disk Electrode (RRDE)
  • Square Wave Voltammetry
  • Staircase Voltammetry

Request a Quote!